Aggregate Sieve Analysis (FM & Zone) & Cube Strength QA/QC Calculator
IS 383 / ASTM C33 Sand Fineness Modulus, Auto Grading Zone I–IV, Silt % Test & IS 456 / IS 516 Concrete Cube Acceptance
| IS Sieve Size | Wt Retained (g) | % Retained | Cum % Retained | % Passing | IS 383 Zone II Limit |
|---|---|---|---|---|---|
| 4.75 mm | 90 – 100% | ||||
| 2.36 mm | 75 – 100% | ||||
| 1.18 mm | 55 – 90% | ||||
| 600 micron | 35 – 59% | ||||
| 300 micron | 8 – 30% | ||||
| 150 micron | 0 – 10% | ||||
| Pan (Receiver) | — | 0.0% | Dust / Silt |
Grain Size Grading Curve vs IS 383 Zone II Recommended Band
How to Use Our Aggregate Sieve Analysis & Concrete Cube Strength Calculator
First, poor concrete quality almost always starts at the batching yard with silty sand or failed compression cubes. Therefore, lab engineers can use our free aggregate sieve analysis calculator for quick QA/QC checks. Simply type raw retained weights (g) for IS 383 sieves from 4.75mm down to 150µm. As a result, you get % Retained, Cumulative % Retained, % Passing, and Fineness Modulus (FM). Moreover, it shows Auto-Detected Zone I–IV, Silt % check, and a live Zone II grading curve SVG.
Next, switch to Tab 2 to verify 7-day or 28-day Concrete Cube Crush Loads (kN). We check your data against IS 456 Cl. 16.1 and IS 516 acceptance criteria. Specifically, the tool verifies average strength, individual minimum strength, and the strict ±15% cube variation rule.
Aggregate Sieve Analysis Calculator: Site Lab QA/QC Acceptance Limits
- Fineness Modulus (Concrete Sand): Ideal concrete sand falls between FM 2.2 and 3.2. For example, Zone II 600 µm passing of
35%–59%works best for RCC slabs and beams. - Silt Content Limit: Field settling silt volume must not exceed 8% by volume. However, keep washed river sand at
≤ 3%because excess silt weakens cement paste bond. - 28-Day Cube Rule (IS 456): First, the 3-cube average must reach at least
fck + 4 MPa. In addition, no individual cube can fall belowfck - 3 MPa, and variation must stay within±15%.
Related Concrete & Material Testing Tools
- First, design M20–M50 concrete batches in our Concrete Mix Design Calculator (IS 10262 & ACI 211).
- Next, look up 20+ lab tolerances in our Construction QA/QC Testing & Density Hub.
Frequently Asked Questions (FAQs)
Which sand grading zone works best for RCC slab and column concreting?
Use IS 383 Zone II sand where 35%–59% passes the 600-micron sieve. Furthermore, a Fineness Modulus between 2.6–2.9 gives ideal workability, density, and low water demand.
What happens if one concrete cube fails the ±15% variation check?
Per IS 456 and IS 516, check whether any cube differs by over ±15% from the three-cube average. Therefore, if it fails, reject that test sample and perform re-evaluation or core testing.